CYBERPOWER HSTP 3 Phase UPS HSTP3T90KE

https://bhinneka.com/web/image/product.product/12846/image_1920?unique=fd9bfd2
3322232541
|
Harga
-

928136000.0 IDR Rp 928.136.000 0% Rp 928.136.000
Harga sudah termasuk PPN

Rp 836.158.559 Termasuk PPN

Not Available For Sale

Cicilan
-
Mulai dari Rp 79.736.770/bulan. Lihat cicilan lainnya
Estimasi
Siap dikirim 2-5 hari
  • Merek
  • Lokasi

Variant ini tidak tersedia.

Total Rp 928.136.000
Anda sudah mencapai maksimal pembelian
Informasi Toko
Dijual dan dikirim oleh Bhinneka, DKI Jakarta
Garansi
2 Years Local Official Distributor Warranty

Syarat dan Ketentuan
Jaminan 30-hari uang-kembali
Pengiriman: 2-3 Hari Kerja

  • Online Double Conversion
  • Capacity 90000VA / 81000W
  • Power Factor 0.9
  • Input 3Ph-400VAC
  • Output 3Ph 400VAC, Three Phase, Serial Port RS232 x 1 + RS485 x 1 + Dry Contact x1, Tower Form Factor
  • Unit Utama
  • Spesifikasi
    Daya Keluar90000VA / 81000W
    Form FactorTower
    Baterai
    • Typical Recharge Power (%) : 20 % x Power
    • Recharge Power Setting : Configurable
    • Smart Battery Management (SBM)
    Voltase Masuk
    • Dual Power Inputs
    • Input Voltage (Vac) : Line to Neutral (L-N): 220 ~ 240 Vac; Line to Line (L-L): 380 ~ 415 Vac
    • Input Voltage Range (Vac) : Line to Neutral (L-N): 132 ~ 276 Vac; Line to Line (L-L): 228 ~ 478 Vac
    • Adjustable Voltage Range (Vac) : Line to Neutral (L-N): 220 ~ 250 Vac; Line to Line (L-L): 380 ~ 435 Vac
    • Input Frequency (Hz) : 50 ± 3; 60 ± 3
    • Input Power Factor 0.99
    Antarmuka / InterfaceRS232 x 1 + RS485 x 1 + Dry Contact x1
    Back-Up Time Full Load10 minutes
    Dimensi Produk600 x 1400 x 980 (WxHxD)
    Voltase Keluar
    • Output Voltage : 380V/400V/415V (Line to Line); 220V/230V/240V (Line to Neutral) (Three Phase)
    • Voltage Precission : +1.5% ~ -1.5% (linear load)
    • Voltage THD (Total Harmonic Distortion) : THD<1% (linear load), THD<6% (nonlinear load)
    • Power Factor : 0.9
    • Crest Factor : 3:1
    • Phase Tolerance : 120o±0.5o (balance and unbalance load)
    • Overload Capability : <105% Long time operation; 105-110% transfer to bypass after 1 hour; 110-125%, transfer to bypass after 10 mins; 125-150% transfer to bypass after 1 mins; >150% transfer to bypass after 200ms
    Lain-lain
    • LCD Setting & Control : Mode Setting , Input & Output , Battery Setting , Communication , Event & Log , Security Setting , Language
    • Double Conversion Online
    • Genset Compatible
    • PowerPanel® Business Edition
    • Dry Contact
    • EPO
    Review