PROLINK Master II 1P/1P UPS PRO810-QS

https://bhinneka.com/web/image/product.product/15941/image_1920?unique=c059370
3323668238
|
Harga
-

44053000.0 IDR Rp 51.827.000 15% Rp 44.053.000
Harga sudah termasuk PPN

Rp 46.690.991 Termasuk PPN

Not Available For Sale

Cicilan
-
Mulai dari Rp 3.784.622/bulan. Lihat cicilan lainnya
Estimasi
Siap dikirim 2-5 hari
  • Merek
  • Lokasi

Variant ini tidak tersedia.

Total Rp 44.053.000
Anda sudah mencapai maksimal pembelian
Informasi Toko
Dijual dan dikirim oleh Bhinneka, DKI Jakarta
Garansi
1 Year Local Official Distributor Warranty

Syarat dan Ketentuan
Jaminan 30-hari uang-kembali
Pengiriman: 2-3 Hari Kerja

  • Online Double Conversion UPS
  • Capacity 3000VA / 3000W, Power Factor 1
  • Input Voltage : 208/220/230/240 VAC
  • Output Voltage : 208/220/230/240 VAC
  • 1 Phase In / 1 Phase Out, Modbus RS-232 or USB
  • Unit Utama
  • Spesifikasi
    Daya Keluar10000VA/10000W
    Form FactorTower
    Baterai
    • Battery Type ; 12V / 9 AH
    • Numbers ; 16
    • Typical Recharge Time ; 9 hours recover to 90% capacity
    • Charging Current (max) : 1.0 A
    • Charging Voltage ; 218.4 VDC ± 1%
    Voltase Masuk
    • Nominal Voltage : 208/220/230/240 VAC
    • Voltage Range : 110-300 VAC @ 0 ~ 60% load; 140-300 VAC @ 60 ~ 80% load; 176-300 VAC @ 80 ~ 100% load
    • Frequency Range : 46 ~ 54 Hz or 56 ~ 64 Hz
    • Phase : Single phase with ground
    • Power Factor : ≥ 0.99 @ full load
    • THDi% : <4% @100% Load ; <6% @50% Load
    Antarmuka / Interface
    • Modbus RS-232 or USB : Supports Windows ® 2000/2003/XP/Vista/2008, Windows ® 7/8/10, Linux and MAC
    • Optional SNMP : Power management from SNMP manager and web browser
    Voltase Keluar
    • Output Voltage : 208/220/230/240 VAC
    • AC Voltage Regulation (Batt. Mode) : ± 1%
    • Frequency Range (Synchronized Range) : 46 ~ 54 Hz or 56 ~ 64 Hz
    • Frequency Range (Batt. Mode) : 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
    • Current Crest Ratio : 3:1 (max.)
    • Harmonic Distortion : ≤1 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load)
    • Transfer Time : AC Mode to Batt. Mode Zero; Inverter to Bypass Zero
    • Waveform (Batt. Mode) : Pure Sinewave
    • Overload : AC Mode : 100%~110% 10min ; 110%~130%: 1min ; >130% : 1sec; Battery Mode 100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec
    Lain-lain
    • 1 Phase In/1 Phase Out
    • LCD Panel : UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
    • Alarm : Battery Mode Sounding every 4 second; Low battery Sounding every second; Overload Sounding twice every second; Fault Continously sounding
    • Humidity : 20-95 % RH @ 0- 40°C (Non-condensing)
    • Noise Level : Less than 50dBA @ 1 Meter
    • Efficiency : AC Mode 94%; Battery Mode 91%
    Review