PROLINK Master II+ 3P/1P UPS PRO83120-ERS

https://bhinneka.com/web/image/product.product/15657/image_1920?unique=6d299eb
3323585303
|
Harga
-

159800000.0 IDR Rp 159.800.000 0% Rp 159.800.000
Harga sudah termasuk PPN

Rp 143.963.964 Termasuk PPN

Not Available For Sale

Cicilan
-
Mulai dari Rp 13.728.522/bulan. Lihat cicilan lainnya
Estimasi
Product Inden
  • Merek
  • Lokasi

Variant ini tidak tersedia.

Total Rp 159.800.000
Anda sudah mencapai maksimal pembelian
Informasi Toko
Dijual dan dikirim oleh Bhinneka, DKI Jakarta
Garansi
1 Year Local Official Distributor Warranty

Syarat dan Ketentuan
Jaminan 30-hari uang-kembali
Pengiriman: 2-3 Hari Kerja

  • Online Double Conversion UPS
  • Capacity 20kVA / 18000W, Power Factor 0.9
  • Input Voltage : 3 x 400 VAC (3Ph+N)
  • Output Voltage : 208/220/230/240VAC
  • 3 Phase In / 1 Phase Out, Smart RS-232 / USB
  • Unit Utama
  • Spesifikasi
    Daya Keluar20000VA / 18000W
    Form FactorRackmount
    Baterai
    • Battery Type 12V/ 9 AH
    • Numbers : 20pcs x 2 strings (18 - 20 pcs* adjustable)
    • Typical Recharge Time : 9 hours recover to 90% capacity
    • Charging Current : 2A
    • Charging Voltage ; 273 VDC ± 1% (based on battery numbers at 20 pcs)
    Voltase Masuk
    • Nominal Voltage : 3 x 400 VAC (3Ph+N)
    • Voltage Range : 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
    • Frequency Range : 46 ~ 54 Hz or 56 ~ 64Hz
    • Power Factor : ≥0.99 @ 100% Load
    • THDi : < 6% @ 100% Load
    Antarmuka / Interface
    • Smart RS-232 / USB : Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux, Unix, and MAC
    • Optional SNMP : Power management from SNMP manager and web browser
    Voltase Keluar
    • Output Voltage : 208/220/230/240VAC
    • AC Voltage Regulation (Batt. Mode) : ± 1%
    • Frequency Range (Synchronized Range) : 46 ~ 54Hz or 56 ~ 64Hz
    • Frequency Range (Batt. Mode) : 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
    • Current Crest Ratio : 3 : 1
    • Harmonic Distortion : "≤2 % THD (Linear Load); ≤5 % THD (Non-Linear Load)"
    • AC Mode to Battery Mode : Zero
    • Inverter to Bypass : Zero
    • Waveform (Batt. Mode) : Pure Sinewave
    Lain-lain
    • Efficiency : Line Mode 91%; ECO Mode 96%; Battery Mode 88%
    • LCD Panel : UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
    • Alarm : Battery Mode Sounding every 4 second; Low battery Sounding every second; Overload Sounding twice every second; Fault Continously sounding
    • Operating Humidity : 0-95 % RH @ 0- 40°C (Non-condensing)
    • Noise Level : Less than 60dB @ 1 Meter
    Review