SIERRA UPS Systems BH60L 6KVA/4.8KW

https://bhinneka.com/web/image/product.product/17813/image_1920?unique=152cb4d
3324501759
|
Harga
-

14560000.0 IDR Rp 14.560.000 0% Rp 14.560.000
Harga sudah termasuk PPN

Rp 13.117.117 Termasuk PPN

Not Available For Sale

Cicilan
-
Mulai dari Rp 768.445/bulan. Lihat cicilan lainnya
Estimasi
Product Inden
  • Merek
  • Lokasi

Variant ini tidak tersedia.

Total Rp 14.560.000
Anda sudah mencapai maksimal pembelian
Informasi Toko
Dijual dan dikirim oleh Bhinneka, DKI Jakarta
Garansi
2 Years Local Official Distributor Warranty

Syarat dan Ketentuan
Jaminan 30-hari uang-kembali
Pengiriman: 2-3 Hari Kerja

  • Double Conversion High Frequency Online, BAT Voltage: 192 VDC
  • Capacity: 6KVA/4.8KW, Input Voltage Range : 175 ~ 280 Vac
  • Output Voltage (AC mode): 220 Vac
  • Output PF: 0.8, Output Waveform: Pure Sinewave
  • LCD/LED Display, Tower
  • Unit utama
  • Spesifikasi
    Daya Keluar6000VA / 4800W
    Form FactorTower
    Baterai
    • Type : Sealed Lead Acid Maintenance Free Battery
    • Ext. Model Rated Voltage/Units : 192Vdc
    • Ext. Model Charging Current : 5A
    Voltase Masuk
    • Input Voltage Range : 175 ~280 Vac
    • Input Frequency Range : 45-65Hz
    • Input PF : 0.99
    • THDI : < 5%
    Berat Produk20 Kg
    Antarmuka / Interface
    • Communication Port : Rs232 (Std.) ; SNMP/RS485/Dry Contact (Optional Accessory)
    • Remote Software : Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remore Control
    Dimensi Produk500 x 240 x 460 mm (WxDxH)
    Voltase Keluar
    • Output Voltage (AC mode) : 220 Vac
    • Output PF : 0.8
    • Output Voltage Regulation : 220 Vac ± 1% (Static Load) ; 220Vac ± 2% (50-0% Sudden Change) ; 220Vac ± 3% (100-0% Sudden Change)
    • Output Frequency (BAT mode) : 50Hz ± 0.2%
    • Output Waveform : Pure Sinewave
    • Distortion : < 1% (Linear Full Load) , < 3% (100% Non Linear Load)
    • Overload : > 120% : More than 1 min, > 150% : 300 ms transfer to bypass
    • > 150% : 300 ms transfer to bypass Crest Ratio : 3 : 1
    • Efficiency : >90%
    • Short Circuit : Circuit Auto Protection, Output Voltage /Current 0
    • Output Abnormal : INV Output Auto-Locked Protection
    • Noise Suppression : EMI/RFI Wave filter
    • BAT Low : Shutdown Protection
    • Dynamic Response : 3% at full load, recovering in 20ms
    • Auto-Restart : Available
    • Software Control : Available
    • Static Bypass Transfer Time : 0ms
    • Static Bypass Range : 80Vac ± 5% ~ 285Vac ± 5%
    • Bypass -> INV Transfer Time : 2ms
    Lain-lain
    • Double Conversion High Frequency Online
    • Overall Efficiency : > 90%
    • Noise (In 2 meters) : < 50 dB
    • Working Temp : 0 - 40 C
    • Storage Temp : -15 - 60 C (without BATs)
    • Humidity : < 95% Non-Condensing
    • Safety Standard : GB/T14715
    • EMC STandard : EN 50091-1/2
    • Protections : Overload, Short-Circuit, Over Temp, Utility Power Voltage High/Low, BAT Voltage High/Low
    • Parallel Redundancy : None
    • Generator Compatibility : Available
    • DC Start : Available
    • Manual Maintenance Bypass : None
    • Alarm : Auto
    • Mute : Auto
    Review