VEKTOR ABLEREX MS II 20 KVA 3/1

https://bhinneka.com/web/image/product.product/30951/image_1920?unique=d8f4bfa
3327308648
|
Harga
-

160959500.0 IDR Rp 160.959.500 0% Rp 160.959.500
Harga sudah termasuk PPN

Rp 145.008.559 Termasuk PPN

Not Available For Sale

Cicilan
-
Mulai dari Rp 13.828.136/bulan. Lihat cicilan lainnya
Estimasi
Siap dikirim 2-5 hari
  • Merek
  • Lokasi

Variant ini tidak tersedia.

Total Rp 160.959.500
Anda sudah mencapai maksimal pembelian
Informasi Toko
Dijual dan dikirim oleh Bhinneka, DKI Jakarta
Garansi
1 Year Local Official Distributor Warranty

Syarat dan Ketentuan
Jaminan 30-hari uang-kembali
Pengiriman: 2-3 Hari Kerja

  • Capacity : 20000VA/16000W
  • Rated Power Factor : 0.8
  • Input Voltage : 277 - 485 Vac
  • Output Voltage : 200/220/230/240 Vac Selectable [208/120 Vac Optional]
  • With Galvanic Isolated Transformer, Standard RS232 Interface
  • Unit Utama
  • Spesifikasi
    Daya Keluar20000VA / 16000W
    Form FactorTower
    Baterai
    • External Battery Cabinet Only
    • Type : Sealed Lead Acid Maintenance Free 12V
    • Capacity : 12V
    • Quantity : 20 pcs or 40 pcs
    • Voltage : 240 Vdc
    • Recharger Time : 5 Hours to 90%
    • Supplementary charger : Optional 1000W Isolated Charger
    Voltase Masuk
    • Voltage : 277 ~ 485 Vac
    • Frequency : 45-65 Hz
    • Phase / Wire : Single, Line + Neutral + Ground
    • Power Factor : Up to 0.99 at 100% Linear Load
    • Current THD : < 5% at 100% Linear Load
    Antarmuka / Interface
    • Standard RS232 Interface
    • 2nd RS232 with EPO**, USB with EPO**, RS485 with EPO**, Relay contact & EPO, SNMP/WEB Card, etc [Optional]
    Dimensi Produk290 x 645 x 748 mm (UPS Module); 290 x 645 x 941 mm (UPS Module with Galvanic Isolated Transformer Option); 290 x 631 x 748 mm (Battery Module)
    Voltase Keluar
    • Voltage : 200/220/230/240 Vac Selectable [208/120 Vac Optional]
    • Voltage Adjustment : Nominal +1%, +2%, +3%, -1%, -2% or -3% adjustable
    • Voltage Regulation : +/- 2%
    • Rated Power Factor : 0.8 lagging
    • Wave From/Distortion : Sine Wave, Voltage THD <3% [no load to full load]
    • Frequency Stability : +/- 0.2% On Inverter Free-Running Mode
    • Frequency Regulation : +/-1Hz, +/-3Hz [programmable by user]
    • Transfer Time : 0msec
    • Crest Factor : 3:1 acceptable
    • Efficiency [AC to AC, Normal] : Up to 90%
    • Efficiency [AC to AC, ECO Mode] : Up to 95%
    • Autonomy [Built-in Battery] : ~15~30 mins depending on Load
    • DC Start : Yes
    Lain-lain
    • Status on LED+LCD : Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, Transferring with Interruption, & UPS Fault
    • Reading on LCD : input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature
    • Self-Diagnostics : Upon Power-on & Front Panel Setting
    • Overload (with simulated thermal tripping I-T curve) : AC Mode : >121% - 150 for 10 sec; >150% immidiately; BaypassMode : >146% - 148% for 5 sec shut down; >149% - 157% for 2 sec shut down; >158% - 176% for 1 sec shut down; >177% - 187% for 0.32 sec shut down; >188% for 0.16 sec shut down
    • Short Circuit : Inverter Switch off immediately
    • Overheat : AC mode : switch off the UPS; Backup Mode : UPS shuts down immediately
    • Battery Low : alarm and switch off
    • Noise Suppression : Complies with EN62040-2
    • Spike Suppression : Complies with EN61000-4-5
    • Audible and Visual : Line Failure, Battery Low, Transfer to Bypass, System Fault Condition
    • Input & Output connection : Hardwire
    • External Battery Connection : Plug & Play
    • Operating Temperature : 0⁰C - 40⁰C
    • Altitude : 0-2000m up to 40⁰C, 3000m up to 35⁰C
    • Humidity : 90% RH Maximum, Non-Condensing
    • Noise : < 50 dB [at 1 meter]